Tel. (902) 742-8994
|
|
| 3.2 The inspector is NOT required to:
|
a. provide any engineering service or architectural service
b. offer an opinion as to the adequacy
of any structural system or component
|
4. Exterior
|
| 4.1 The inspector shall:
|
A. inspect
|
1. the exterior wall covering, flashing, and trim
2.
all exterior doors
3. attached decks, balconies, stoops, steps, porches, and their associated railings
4. the eaves, soffits, and fascias
where accessible from the ground level
5. the vegetation, grading, surface drainage, and retaining walls on the property when any of
these are likely to adversely affect the building
6. walkways, patios, and driveways leading to dwelling entrances
|
| B. describe the exterior
wall covering
|
| 4.2 The inspector is NOT required to:
|
A. inspect
|
1. screening, shutters, awnings, and similar seasonal accessories
2.
fences
3. geological, geotechnical or hydrological conditions
4. recreational facilities
5. outbuildings
6. seawalls, break-walls, and
docks
7. erosion control and earth stabilization measures |
|
5. The Roof System
|
| 5.1 The inspector shall :
|
| A. inspect
|
1. the roof covering
2.
the roof drainage systems
3. the flashings
4. the skylights, chimney's, and roof penetrations
|
| B. describe the roof covering and report the
methods used to inspect the roof.
|
| 5.2 The inspector is NOT required to:
|
| A. inspect
1. antennae
2. interiors of flues or chimneys which
are not readily accessible.
3. other installed accessories
IF YOU ARE BUYING A HOME, YOU NEED A PROFESSIONAL CAHPI HOME INSPECTION.
6. Plumbing System
6.1. The inspector shall:
A. Inspect
1. the interior water supply and distribution systems including all fixtures and faucets.
2. the drain, waste, and vent systems including all fixtures.
3. the water heating equipment.
4. the vent systems, flues, and chimneys
5. the fuel storage and fuel distribution
systems
6. the drainage sumps, sump pumps, and related piping.
|